B14E1 DTC

Communication error with cluster switch No.2

Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
  • 1. Malfunction in wiring harness (including connector/terminal) between cluster switch No.2 and instrument cluster (See CIRCUIT

B14E1:49 [BCM]

SM3339526

id990210125500

System malfunction location

Cluster switch No.2 malfunction

Detection condition
• The instrument cluster detects a cluster switch No.2 malfunction.
Fail-safe
• Not applicable
Possible cause
1. Cluster switch No.2 malfunction (Refer to [POSITION MEMORY SWITCH INSPECTION] in workshop manual.) (Refer to [POWER LIFTGATE (PLG) FRONT SWITCH INSPECTION] in workshop manual.) (Refer to [TRUNK LID OPENER SWITCH INSPECTION] in workshop manual.)
Repeatability verification procedure
1. Clear the DTC recorded in the memory. (See CLEARING DTC.)
System wiring diagram
• Not applicable