B14E0 DTC

Communication error with cluster switch No.1

Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
  • 1. Malfunction in wiring harness (including connector/terminal) between instrument cluster and cluster switch No.1 (See CIRCUIT

B14E0:13 [BCM]

SM3339762

id990210576100

System malfunction location

Cluster switch No.1 circuit malfunction

Detection condition
• The Instrument cluster detects an open circuit in the cluster switch No.1 circuit.
Fail-safe
• Not applicable
Possible cause
1. Malfunction in wiring harness (including connector/terminal) between instrument cluster and cluster switch No.1 (See CIRCUIT INSPECTION.) (See CONNECTOR INSPECTION.)
2. Cluster switch No.1 malfunction (Refer to [PARKING SENSOR OFF SWITCH INSPECTION] in workshop manual.) (Refer to [i-ACTIVSENSE OFF SWITCH INSPECTION] in workshop manual.) (Refer to [TCS OFF SWITCH INSPECTION] in workshop manual.) (Refer to [DSC OFF SWITCH INSPECTION] in workshop manual.) (Refer to [i-stop OFF SWITCH INSPECTION] in workshop manual.) (Refer to [360°VIEW MONITOR SWITCH INSPECTION] in workshop manual.)
Repeatability verification procedure
1. Clear the DTC recorded in the memory. (See CLEARING DTC.)
image
1
Instrument cluster
2
Cluster switch No.1