B14E0:13 [BCM]
id990210576100
| System malfunction location |
Cluster switch No.1 circuit malfunction |
|---|---|
|
Detection condition
|
• The Instrument cluster detects an open circuit in the cluster switch No.1 circuit.
|
|
Fail-safe
|
• Not applicable
|
|
Possible cause
|
1. Malfunction in wiring harness (including connector/terminal) between instrument cluster and cluster switch No.1 (See CIRCUIT INSPECTION.) (See CONNECTOR INSPECTION.)
2. Cluster switch No.1 malfunction (Refer to [PARKING SENSOR OFF SWITCH INSPECTION] in workshop manual.) (Refer to [i-ACTIVSENSE OFF SWITCH INSPECTION] in workshop manual.) (Refer to [TCS OFF SWITCH INSPECTION] in workshop manual.) (Refer to [DSC OFF SWITCH INSPECTION] in workshop manual.) (Refer to [i-stop OFF SWITCH INSPECTION] in workshop manual.) (Refer to [360°VIEW MONITOR SWITCH INSPECTION] in workshop manual.)
3. Instrument cluster malfunction (Refer to [INSTRUMENT CLUSTER INSPECTION] in workshop manual.)
4. Body control module (BCM) malfunction (Refer to [BODY CONTROL MODULE (BCM) REMOVAL/INSTALLATION] in workshop manual.)
|
|
Repeatability verification procedure
|
1. Clear the DTC recorded in the memory. (See CLEARING DTC.)
|
![]() |
|
|
1
|
Instrument cluster
|
|
2
|
Cluster switch No.1
|