B144F:62 [BCM]
id990210122500
| System malfunction location |
Difference malfunction between power liftgate (PLG) drive unit right and left |
|---|---|
|
Detection condition
|
• The power liftgate (PLG) control module counts the difference between power liftgate (PLG) drive unit right and left for the standard or more.
|
|
Fail-safe
|
• Stops the power liftgate (PLG) system operation.
|
|
Possible cause
|
1. Malfunction in wiring harness (including connector/terminal) between power liftgate (PLG) drive unit (LH) and power liftgate (PLG) control module (See CIRCUIT INSPECTION.) (See CONNECTOR INSPECTION.)
2. Malfunction in wiring harness (including connector/terminal) between power liftgate (PLG) drive unit (RH) and power liftgate (PLG) control module (See CIRCUIT INSPECTION.) (See CONNECTOR INSPECTION.)
3. Power liftgate (PLG) drive unit (LH) malfunction
4. Power liftgate (PLG) drive unit (RH) malfunction
5. Power liftgate (PLG) control module malfunction (Refer to [POWER LIFTGATE (PLG) CONTROL MODULE INSPECTION] in workshop manual.)
6. Body control module (BCM) malfunction (Refer to [BODY CONTROL MODULE (BCM) REMOVAL/INSTALLATION] in workshop manual.)
|
|
Repeatability verification procedure
|
1. Clear the DTC recorded in the memory. (See CLEARING DTC.)
|
![]() |
|
|
1
|
Power liftgate (PLG) control module
|
|
2
|
Power liftgate (PLG) drive unit (LH)
|
|
3
|
Power liftgate (PLG) drive unit (RH)
|