B11E9 DTC

Rear door latch switch (LH) circuit malfunction

Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
Component Connector
  • 1. Rear door latch switch (LH) malfunction (Refer to [REAR DOOR LATCH AND LOCK ACTUATOR

B11E9:11 [BCM]

SM3339466

id990210113500

System malfunction location

Rear door latch switch (LH) circuit malfunction

Detection condition
• The electrical supply unit (ESU) detects a short to ground in the rear door latch switch (LH) circuit for a continuous 2 times.
Precondition
• The rear door (LH) closed (rear door latch switch (LH) off).
Fail-safe
• Not applicable
Possible cause
2. Malfunction in wiring harness (including connector/terminal) between rear door latch and lock actuator (LH) and electrical supply unit (ESU) (See CIRCUIT INSPECTION.) (See CONNECTOR INSPECTION.)
Repeatability verification procedure
1. Clear the DTC recorded in the memory. (See CLEARING DTC.)
2. Close the rear door (LH).
image
1
Electrical supply unit (ESU)
2
Rear door latch and lock actuator (LH)