B1176:11 [BCM]
id990210112400
| System malfunction location |
Front door latch switch (passenger's side) circuit malfunction |
|---|---|
|
Detection condition
|
• The door-electrical supply unit (passenger's side) detects a short to ground in the front door latch switch (passenger's side) circuit for a continuous 2 times.
Precondition
• The front door (passenger's side) closed (front door latch switch (passenger's side) off).
|
|
Fail-safe
|
• Not applicable
|
|
Possible cause
|
1. Front door latch switch (passenger's side) malfunction (Refer to [FRONT DOOR LATCH AND LOCK ACTUATOR INSPECTION] in workshop manual.)
2. Malfunction in wiring harness (including connector/terminal) between front door latch and lock actuator (passenger's side) and door-electrical supply unit (passenger's side) (See CIRCUIT INSPECTION.) (See CONNECTOR INSPECTION.)
3. Door-electrical supply unit (passenger's side) malfunction (Refer to [DOOR-ELECTRICAL SUPPLY UNIT REMOVAL/INSTALLATION] in workshop manual.)
4. Body control module (BCM) malfunction (Refer to [BODY CONTROL MODULE (BCM) REMOVAL/INSTALLATION] in workshop manual.)
|
|
Repeatability verification procedure
|
1. Clear the DTC recorded in the memory. (See CLEARING DTC.)
2. Close the front door (passenger's side).
|
![]() |
|
|
1
|
Door-electrical supply unit (passenger's side)
|
|
2
|
Front door latch and lock actuator (passenger's side)
|